XP POWER CDX Series 1500W Dual Frequency RF Power Supply
Product Overview
Product Name: CDX Series Dual Frequency RF Power Supplies
Core positioning: High power, high-precision power supply equipment designed for industrial scenarios that require dual frequency RF drive, such as semiconductors, plasma processing, etc
Core advantages: flexible dual band selection, high output accuracy and stability, multi communication interface adaptation, compatibility with harsh environments and compliance
Physical and installation characteristics:
Dimensions: 483mm x 133mm x 457mm (19 “W x 5.25” H x 18 “D)
Weight: Maximum 18kg (39lb.)
Installation method: Standard 19 inch EIA rack mounted
Appearance: Full surface painted or galvanized chromate coating, equipped with dual handles at the front end
Warning signs: IEC standard safety signs including dangerous voltage, heavy objects, high temperature, and radio frequency energy
Electrical specification details
(1) Input parameters
Characteristic specification remarks
Input voltage 208/400/480VAC, three-phase without neutral wire, with grounding
Input frequency 50/60Hz nominal value
Input current 7.5A/phase based on 480VAC input, varying with output specifications
(2) Output parameters
Characteristic specification remarks
Single output power up to 1500W continuous forward power, 50 Ω load
Output accuracy/adjustment ± 2W or ± 1.0% (whichever is greater) 10% -100% maximum output range
Short term stability ± 1.0% continuous output for 1 hour, 10% -100% set point
Long term stability ± 3.0% continuous output for 3 years, 10% -100% set point
Rise time<200ms from enable signal front to 90% requested power
Available frequencies (per channel): 400kHz, 2MHz, 13.56MHz, 27.12MHz, 40.68MHz, 60MHz. Any two frequencies can be selected
Frequency stability ± 0.005%-
Zero set point output<1.0W actual power,<1.0W read back power when the set signal is zero or negative
Harmonic signal<-40dBc-
Stray signal<-40dBc-
AM&FM noise<-40dBc at 50kHz offset
Heat dissipation and environmental requirements
(1) Heat dissipation parameters
Detailed remarks on heat dissipation method requirements
Cooling type: mandatory requirement for water cooling, alternative option without air cooling
The minimum inlet flow rate is 8.6L/m (2GPM) and the maximum pressure is 414kPa (60psi)
Inlet water temperature: 5 ° C-25 ° C (40 ° F-77 ° F). Water temperature exceeding the range may affect heat dissipation efficiency
Explanation on no special water quality requirements for cooling medium water
(2) Environmental adaptability
Environmental conditions, work scope, storage/transportation scope
Temperature 10-40 ° C (50-104 ° F) -25-70 ° C
Humidity 5-85% RH (non condensing, non freezing) 5-95% RH (non condensing, non freezing)
Air pressure 86-106kPa 70-106kPa
The maximum intake requirement is 30 ° C (95 ° F)-
Standard Class Temperature/Humidity/Air Pressure Class 3K3 (prEN50178) Temperature Class 1k4, Humidity Class 1k3, Air Pressure Class 1k4
Function and Interface
(1) Core functions
Optional features: Pulse mode operation (single-stage/multi-stage/synchronous/advanced envelope control), frequency agility, automatic frequency tuning (minimizing reflected power), fast shutdown (arc management), common exciter (CEX, multi power synchronous clock)
Safety and status monitoring: Front end LED indicator lights (AC on, RF on, interlock status, fault status), 20 × 2 character alphanumeric display screen (displaying all operating parameters)
(2) Communication and Connection Interface
Interface Type Specification Details Usage
Digital communication DeviceNet (M12 interface), EtherCAT industrial bus control and data transmission
Serial communication RS232 point-to-point serial control
Analog interface, analog signal input/output, analog quantity control, and power feedback
Other interfaces include 15PIN I/O, 10-32 grounding column, HARTING/HAN 40 3PE (power input) expansion I/O, grounding, and power access
Compliance and Certification
Safety compliance: EN 61010-1:2010, UL 61010-1:2012, CSA C22.2 No. 61010-1:2012
Performance compliance: Passed SEMI F47-0200 voltage drop immunity test to meet Samsung Power Vaccine requirements
Certification mark: Compliance system with TUV safety/EMC mark (compliant with the latest international standards)