Uncategorized

XP POWER MP Series AC-DC Power Supply

Product Overview

Product Name: XP MP Series AC-DC Power Supply

Power range: 300-2400 Watts (additional power can be increased when the high input voltage is 181-264VAC, such as F3+200W)

Core advantages: Supports 1-24 outputs, floating output design, SEMI F47 compliance (high input voltage only), 3-year warranty, MTBF up to 750000 hours, suitable for global critical system power supply needs

Security and EMC certification:

Specific standards for certification types

Safety certification EN62368-1, UL62368-1, CSA62368-1 (cUL), CE, UKCA

EMC emissions EN55032 Level B (conduction)

Electromagnetic Immunity EN61000-4 Series (ESD/Radiation/EFT Level 3, Performance Standard A)

Harmonic/flicker EN61000-3-2 Class A, EN61000-3-3

Electrical specification details

(1) Input parameters

Input voltage: 90-264 VAC (wide voltage range)

Input frequency: 47-63 Hz

Surge current: Maximum 40A at 230VAC cold start (25 ℃)

Power factor: Complies with EN61000-3-2 Class A

Leakage current:<1.5 mA

Input protection: built-in fuse (differentiated by chassis model)

Chassis model, fuse specifications

F3/FF T6.3A/250V

F4/F6 T10A/250V

F7 T12A/250V

F8 T15A/250V

FX T20A/250V

(2) Output parameters

Output voltage: Depending on module type (2-60V), supports ± 5% voltage fine-tuning

Adjustment accuracy:

Line adjustment: typical 0.1%, maximum 0.3%

Load regulation: Single output and dual/triple output V1 maximum 1%; Dual/triple output V2/V3 maximum 2% (E module V1 requires ≥ 10% load, K module V1 requires ≥ 5% load)

Ripple and noise: 50mV or 1% pk pk (whichever is greater), 20MHz bandwidth

Holding time: minimum 20ms

Temperature coefficient: 0.03%/° C

Protection function:

Overvoltage protection (OVP): Single and dual/triple V1 are 115-130% Vnom (G/H module has no OVP)

Overload protection:<150% rated power

Short circuit protection: continuous tripping+restart (hiccup mode)

(3) Isolation characteristics

Input output: 3000 VAC

Input ground: 1500 VAC

Output ground: 500 VAC

Configuration plan (chassis+module+options)

(1) Chassis selection (classified by power)

Chassis model, rated power, high voltage, additional power, applicable module quantity

F3 300W+200W 1-3 pieces

FF 350W+175W 1-3 pieces

F4 400W+200W 1-4 pieces

F6 600W+150W 1-4 pieces

F7 700W+200W 1-4 pieces

F8 800W+200W 1-6 pieces

FX 1000W+200W 1-6 pieces

(2) Output module type

Single output module: A/J/B/C/H series, voltage 2-60V, current 2-100A (example: B3)= 5V@60A , JG= 10V@18A )

Dual output module: G/K/D series, maximum power 150W (example: G2)= 15V@3A + 15V@3A , K2= 5V@10A + 12V@8A )

Three output modules: E series (Example: E1)= 5V@20A + 12V@2A + 12V@2A )

(3) Option code (function extension)

Function description of option code

01-06 Parallel connection of B/C modules (e.g. 01=1-2 slots parallel connection of B modules)

21-25 J modules in parallel (such as 22=2-3 slot J modules in parallel)

1R reverse airflow (standard fan exhaust)

1S low noise (only F8/FX, standard intake)

2R Reverse Low Noise Airflow (F8/FX Only)

Environmental and mechanical parameters

(1) Environmental adaptability

Operating Temperature

Standard model: 0 ° C to+70 ° C (50% power when linearly rated to 70 ° C after 50 ° C)

Reverse airflow model: 40 ° C to+60 ° C (50% power when linearly rated to 60 ° C after 40 ° C)

Storage temperature: -40 ° C to+85 ° C

Working altitude: 3000 meters

Impact resistance: 30g, 11ms (half sine wave), 3 times per axis, a total of 18 times (EN60068-2-27)

Vibration resistance: 2g, 10-500Hz, 10 scans on each of the 3 axes (EN60068-2-6)

(2) Mechanical details

Size and weight (example):

Chassis model size (inches/millimeters) Weight (lb/kg)

F3(300W) 8.88×5.00×4.20(225.6×127.0×106.7) 2.80/1.27

FF(350W) 9.94×5.00×4.20(252.5×127.0×106.7) 3.95/1.80

F8(800W) 11.00×7.00×6.20(279.4×177.8×157.5) 3.96/1.80

Connectors: AC input (Molex 26-60-7050), standby output (Molex 39-01-4033), logic connector (AMP 87631-5), etc

Signal and control functions

Core signals: AC OK (power failure warning ≥ 5ms), DC OK (output voltage compliance indication), current sharing (single wire parallel), global prohibition, module prohibition, remote induction, voltage programming, 5V standby output

Remote sensing: supported by A/J/B/C/K and E modules V1 (compensating for a maximum voltage drop of 0.5V); D module supports return line voltage drop compensation (maximum 0.25V); H/G and E modules V2/V3 do not have this function

Module parallel/series connection: Single channel module and dual/triple channel module V1 can be connected in parallel to increase current; Single module can be connected in series to increase pressure (>80V, please consult sales)