Uncategorized

Rexroth IndraDrive-C HCS02.1/HCS03.1 Operation and Debugging

Product Introduction

Hardware platform composition

Power units: HCS02.1E (low power, 300mm casing), HCS03.1E (high power, 400mm casing);

Control unit: BASIC OPENLOOP (FC interface) BASIC PROFIBUS‑DP(PB), Directly plugged into the power unit;

Supports the full range of IndraDyn synchronous/asynchronous motors (shell motors, frameless kit motors) from Rexroth, as well as third-party motors.

Encoder support: EnDat, Hiperface, 1Vpp sine, TTL square wave, rotary transformer, SSI, etc; Distinguish between motor encoders and external measurement encoders.

PROFIBUS-DP master-slave communication: supports periodic reading and writing to fixed/actual values, non periodic parameter channels, optional PROFIsafe secure channel, with a minimum cycle period of 500 μ s.

The firmware MPB-04 function package is divided by function package: basic open-loop/closed-loop, spindle package MSP, synchronous function package SNC, fully extended ALL, and built-in PLC IndraMotion MLD-S.

Supporting operating modes: torque, speed, cycle position, internal positioning block of the driver, electronic cam, phase synchronization, virtual spindle synchronization, etc;

Internal control cycle: current loop 125 µ s, speed loop 250 µ s, position loop 500 µ s; enabling MLD-S or SNC synchronization function will automatically downgrade to Economy economic performance level.

Third party motor usage conditions

Support rotating/linear synchronous and asynchronous motors;

Need to verify the insulation withstand voltage dv/dt, minimum phase inductance, and temperature detection of the motor; Insufficient inductance requires external three-phase reactors;

Synchronous motors must measure the commutation offset angle; The manufacturer does not guarantee the output power of third-party motor shafts.

Certification: CE (Low Voltage, EMC Directive), C-UL-US certification.

Basic concepts of driver software

IDN parameter system: All configurations, given values, and actual values are mapped to IDN parameters; Divided into S-xxxx system parameters and P-xxxx device parameters;

Storage: non-volatile storage for the controller+built-in memory for the motor encoder; Support load defaults to load motor default parameters from the encoder;

Three level password mechanism: customer password, control password, master password (can modify management protection parameters);

Command: Cxxx command, used for tuning, resetting, and configuring, must be manually cleared after execution;

Warning: Do not automatically shut down (except for fatal warnings);

Error classification: F2xxx non fatal, F3xxx safe non fatal, F4xxx interface, F6xxx trip, F7xxx safety fault, F8xxx fatal, F9xxx system fatal;

Error memory: Save the last 50 errors and their timestamps; The error message will not be automatically cleared and requires a reset command or the ESC button on the panel.

Usage Standards

Compliant use: Used for industrial equipment such as machine tools, handling, packaging, printing, etc., to achieve single/multi axis drive control; Cables and accessories must be specified in the manual and operated under specified environmental conditions.

Prohibited use scenarios: underwater, over temperature and over environmental conditions; Without written permission from Rexroth, it cannot be used in high-risk scenarios such as elevators, healthcare, nuclear power, mining, etc; Misuse will result in loss of warranty, and all risks will be borne by the equipment manufacturer.

General Safety Instructions for Electrical Drivers

Following ANSI Z535 hazard classification DANGER/Warning/CAUTION, for the general safety chapter of Rexroth Drive:

High voltage electric shock risk: Parts with voltage greater than 50V are only for maintenance by certified personnel; Wait for 30 minutes for the capacitor to discharge before touching after power failure; Protective earth wire ≥ 10mm ² copper conductor; Prohibit the use of RCD leakage protectors; The low-voltage interface can only be connected to PELV isolation equipment.

Unexpected motion risks: Wiring, parameter, encoder, and firmware failures can all cause unexpected motion; Emergency stop, safety fence, and grating must be configured; The vertical axis must be equipped with an external mechanical brake/locking mechanism, and the built-in brake of the motor is not sufficient to ensure personal safety; Power off and lock during maintenance.

Magnetic field risk: Personnel wearing pacemakers, metal implants, and hearing aids are prohibited from approaching areas where motors are assembled, operated, or stored.

High temperature burns: Drivers, reactors, and brake resistors need to be fully cooled before touching after shutdown.

Safety regulations for handling, batteries, and compressed media; The manufacturer of the entire machine is responsible for ensuring that it complies with local safety and EMC regulations.

Model Identification, Transportation and Storage, Installation Environment

Nameplate: The power unit, control unit, and firmware have independent nameplates respectively; Provide coding rules for accessory models such as HCS, CSB, HNL, HNF, HLR, HMF, etc.

Transportation and storage conditions

Transportation: -25~70 ℃; Impact 10g/11ms; Prohibit condensation and freezing;

Long term storage: -25~55 ℃; Long term idle: It is recommended to power on for at least 1 hour per year to improve the aging of electrolytic capacitors.

Working environment conditions

IP20, Cabinet installation; The benchmark temperature is 0-40 ℃, and the maximum temperature needs to be reduced to 55 ℃; Altitude>1000m, downgrading up to 4000m;

Provide temperature derating curve and altitude derating curve; Multiply two derating coefficients at high temperature and altitude simultaneously;

Vibration impact, pollution level 2; Pay attention to conducting material compatibility tests with lubricating oil and cleaning agents inside the cabinet.

Electrical Technical Data

5.1 Power Unit HCS02.1/HCS03.1

Main power supply: HCS02 supports single-phase/three-phase 200-500VAC; HCS03 is limited to three-phase 400-500VAC only;

24V control power supply; Provide the rated output current, peak current, incoming fuse, and matching incoming reactor HNL selection for each model;

Maximum allowable length of motor cable: strongly related to PWM switching frequency; The higher the switching frequency, the shorter the cable is allowed; Can be paired with HMF motor filters to increase the allowable cable length, suppress dv/dt, and protect motor insulation;

Example: 4kHz carrier, shielded cable maximum 75m; 12kHz only 25m.

5.2 Control Unit CSB01.1N

Relay output: specifications, load, and lifespan of 3 types of relay contacts;

Digital I/O: compliant with IEC61131-1 type 1 input; High side digital output with short circuit and overload protection;

Analog I/O: Multiple types of analog inputs (voltage, current), analog outputs; Provide resolution, bandwidth, error, and impedance parameters.

5.3 Electrical parameters of supporting peripherals

Inlet filter HNF/HNK, inlet reactor HNL;

Braking resistor HLR series: complete model parameters, continuous power, peak power, energy absorption capacity; Provide the selection chart of braking resistors corresponding to each power unit of HCS02-03 (duty cycle peak power/absorbed energy curve);

Motor filter HMF: suppresses output voltage spikes dv/dt, provides current, inductance, du/dt indicators, and terminal torque.

Mechanical Installation and Electrical Wiring

Mechanical dimensions: HCS02, HCS03, HNF, HNL, HLR, HMF, all external shapes, openings, and installation hole position drawings;

Ventilation distance inside the cabinet: the minimum distance for ventilation above and below the driver; Minimum lateral clearance for parallel installation of different modules; Calculation method for the influence of the heat generated by the braking resistor on the temperature of surrounding components;

Multi driver layout rule: high-power drivers should be placed as close as possible to the power supply unit; HAS attachments occupy additional space;

EMC Installation Specification (Key)

Grounding: star grounding, power grounding, signal grounding processing; Requirements for protective grounding conductors;

Cable laying: Power cables and signal cables are routed separately; 360 ° large-area crimping of shielding layer;

24V control power supply wiring; Surge suppression of inductive loads in relays and contactors;

Complete wiring diagram and connector pin definitions; HAS accessory kit.

Debugging and Parameterization

Debugging methods: Comfort operation panel, IndraWork-D debugging software, upper main station;

Explanation of parameter mode and operation mode; Load Defaults: The complete process of loading motor default parameters from the motor encoder memory;

Panel menu structure; Large IDN parameter index (S-0-0xxxx system parameters, P-0-xxxx device parameters);

Basic functions: serial communication, master station communication, configuration profile; Motor control, physical quantity scaling conversion;

U/f open-loop voltage control mode: suitable for asynchronous motor operation without encoder; Automatic identification of motor parameters;

Closed loop axis control mode: with encoder closed-loop; Automatic axis tuning process;

Positioning block mode: The driver stores positioning blocks internally and does not require real-time interpolation from the upper level.

Diagnosis, Service, and Fault Handling

Diagnostic system: status messages, command messages, warnings, error messages; The driver response corresponding to each error classification (shutdown, optimal deceleration torque, etc.);

Troubleshooting: Steps for troubleshooting the drive body, cables, and motor; Equipment replacement process;

Firmware update: Two update modes (Release version upgrade, Version version upgrade); The fault phenomenon and countermeasures of firmware download failure;

Maintenance, shutdown, disassembly, and disposal; Requirements for environmentally friendly recycling of electronic components and batteries.

Leave a Reply

Your email address will not be published. Required fields are marked *