Bosch Rexroth D8_5… (EDD-XZ) electromagnetic directional valve

Product Overview

Structural form: Stacked valve unit, wet electromagnetic coil with detachable and insertable coils; The spring is aligned, and the valve core returns to the neutral position after losing power. The coil can rotate 180 ° around the electromagnetic iron pipe. AC power supply requires RAC rectifier accessories to drive the coil.

Optional configuration

Optional secondary valve: anti cavitation valve VUM; Direct acting overflow valve VMA with anti cavitation (secondary valves must be paired for ports A and B);

Optional LS load sensing channel;

Manual emergency operation: button type 0P, screw press type 0F;

Valve core position sensor (see also sample RE18300-30).

Interface form: G1/2 pipe thread, SAE10 thread, flange connection version M.

Specification limit

Maximum pressure at pump port: 310   bar; A/B execution port has a maximum pressure of 380 bar; The maximum pressure at the T return port is 250 bar

Maximum flow rate: 80 L/min

Weight: Dual electromagnetic version 3.00 kg; Single electromagnetic version 2.35 kg.

Order coding rules

Code segmentation: D 8 5- [Configuration] – [Valve core type] – [Voltage code] – [Connector code] – [Oil port] – [A-port secondary valve] – [B-port secondary valve] – [Additional options]

Series: D8-5=EDD-XZ valve unit;

Diameter: 8 (Size8);

Configuration: 0 standard; 4 channels with LS load sensing;

Valve core type:

Valve core model: B201/E201/K201/E2R1; B301/E301/K301/X301/Y301; B401/E401/K401/Y401, etc., corresponding hydraulic symbols are provided for the samples.

_Electromagnetic drive on both sides (three position four-way)

_3__: 4/2 only A-side electromagnet (two position four-way)

_4__: 4/2 only b side electromagnet (two position four-way)

Coil voltage code:

Code voltage description

00 Wireless Circle

OB 12 DC 

AD 13 DC 

OC 24   DC is the most commonly used

AC 27 DC 

OD 48 DC 

OV 24 AC (21.5 VDC rectified by RAC) requires RAC

OW 110 AC (98 VDC rectified by RAC) requires RAC

OZ 230 AC (207 VDC rectified by RAC) requires RAC

Electrical connector code:

00: Without coil

01:DIN‑EN175301‑803, Without matching plug

03: AMP Junior bidirectional diode, no plug

07:DEUTSCH DT04‑2P, Bidirectional diode, no plug

31:350mm bipolar sheathed lead out cable

Please order the matching plug separately, refer to RE18325-90.

Oil port form:

2:G1/2 DIN3852; D:SAE10; M: Flange type (A-B-T flange interface)

A-port secondary valve: 0 none; 1 VUM anti air hole; M-X represents the set pressure of VMA relief valve (140-250 bar).

B-port secondary valve: configured in pairs with A-port, with the same code as above. ten Additional options: No code=No options; 0P button manual override; 0F screw type manual override.

Important constraint: As long as port A is equipped with a secondary valve, port B must also be equipped with a secondary valve; The maximum flow capacity of VMA overflow valve is 30 L/min; Refer to RE18329-11/RE18329-51 for secondary valve characteristics.

Working principle

The valve consists of a stacked shell, a slide valve core, a reset spring, and an electromagnet; Spring chamber returns oil through T.

The electromagnet is powered on and drives the valve core to change direction, achieving P to supply oil to A/B and corresponding B/A to return oil to T.

The electromagnet loses power, and the reset spring pushes the valve core back to the center position.

Manual push rod: In case of power failure/malfunction, the valve core can be mechanically pushed to change direction.

Secondary plug-in valve VMA/VUM: Integrated overflow protection+anti cavitation oil replenishment, with reverse one-way function, fast response speed.

Complete technical specifications

Hydraulic parameters

Project values

Maximum pressure at P port 310   bar

A/B port maximum pressure 380   bar

The maximum pressure at the T return port is 250   bar

Maximum flow rate of 80 L/min

Oil HL/HLP mineral oil; Environmentally friendly fluids require consultation with manufacturers

Oil temperature (NBR seal) -20…+80 ℃

Environmental temperature (NBR) -20…+50 ℃

Viscosity 5-420 mm ²/s

Oil cleanliness ISO4406 20/18/15; NAS1638 class9

Electrical parameters

The insulation level of the coil is H, and the maximum allowable temperature of the coil is 150 ℃; Continuous working system, environment ≤ 50 ℃.

Voltage tolerance: nominal voltage -10%~+10%.

The power consumption of all coils is 36   W; the coil current and resistance corresponding to different voltages are shown in the table.

Joint protection: 01 type IP65 after correctly assembling the plug; 07 (DT) IP69K.

AC coils must use RAC rectifier components and cannot be directly connected to AC.

The sample table of coil material numbers is fully listed, such as OC01 (24VDC DIN plug) material R93300076.

Performance curve

Test conditions: ISO-VG32 hydraulic oil, 45 ° C.

Pressure drop flow curve: Different valve cores B/E/K/X/Y correspond to different curve numbers, providing Δ p-Q for each path P>A, P>B, A>T, and B>T.

Pressure flow performance limit curve: allowable pressure flow boundary for each valve core; The curve is based on the symmetric flow condition of P>A and B>T, while the performance of other circuit connection conditions may vary.

Appearance and installation dimensions

The total length of the double electromagnet is 253.6 mm; provide G1/2, SAE10, and flange M version views.

Key installation torque

Coil locking round nut: 5   Nm ± 10%

Secondary overflow valve: 25-30 Nm

Flange M version M6 bolt 8.8 grade: 9-10 Nm

Screw type manual override 0F: 6-7 Nm

Manual override spare parts materials:

Button 0P: R933000043

Screw 0F: R933007215

LS version view: with LS oil port; The coil can be rotated 180 ° to adjust the direction of the output line.