Bosch Rexroth VT-MSPA Proportional Valve Amplifier
Product model and material
Order code format: VT-MSPA – {1/2} -2X/{A5/F5}/000/000
MSPA1: Single electromagnetic drive (pressure valve, variable pump)
MSPA2: Dual electromagnetic drive (4WRA and other bidirectional proportional directional valves)
A5: Voltage command input (single electromagnet 0…+10 V; double electromagnet 0… ± 10 V)
F5: Current command input 4-20 mA
Model Material Number
VT‑MSPA1‑2X/A5/000/000 R901439034
VT‑MSPA1‑2X/F5/000/000 R901439036
VT‑MSPA2‑2X/A5/000/000 R901439037
VT‑MSPA2‑2X/F5/000/000 R901439038
Main functional features
Command input: differential voltage 0… ± 10 V or 4-20 mA current; Has reverse polarity protection.
Slope generator: supports single slope mode (shared by all quadrants) or 4-quadrant independent slopes (positive and negative rise, positive and negative fall are set separately); The slope time range is 0.01-30 seconds. The slope does not change the characteristic curve of the valve.
Zero offset Z/B: Zero/pilot current adjustment, with an adjustment range of ± 10%.
Instruction decay G: Scale the external given instruction by 70-110%.
Step level S: Set the output step current to 0-50% to overcome the valve dead zone.
Built in valve characteristic curve generator: rotate dial to select valve model, call pre stored valve characteristics; Expert mode can also fine tune the pilot current, step level, and maximum electromagnetic current; The A/B electromagnets of VT-MPCA2 can independently set the maximum current.
Current closed-loop controller: Real time collection of the actual current of the electromagnet, and closed-loop adjustment with instructions.
PWM clock output stage: clock frequency 95-505 Hz (automatically adapted with valve model/supply voltage); Output short circuit protection; Cable breakage detection.
The digital input DI can be configured with four functions: enable/reverse command/ramp switch/single/four quadrant ramp switching.
Digital output ready: Output a ready signal when there are no internal faults, the cable is intact, and the power supply is normal.
Panel human-machine interface: LED status indicator light, SET confirmation button,+/- parameter increase/decrease button, valve type rotary dial; The measuring socket can measure: the actual current Ia of the internal given v and A electromagnet, and the actual current Ib of the B electromagnet.
Hardware structure and terminals
Appearance: DIN TH35 rail module, glass fiber reinforced nylon shell, weight 0.14 kg; protection IP20.
Connectors: 3 sets of spring plug terminals XH1 (power supply+electromagnet), XH2 (DI/DO), X2A (analog given, actual value output).
Terminal allocation:
XH1: Power supply 24VDC, electromagnetic coil B ±
XH2: Digital input DI, Ready output, Electromagnetic coil A ± (MSPA2 only)
X2A: ± instruction given input; ± Actual value analog output (0~± 2.5 V, representing electromagnetic current)
Front panel components:
LED status indicator array;
SET button: Confirm parameters and enter expert mode;
+/-Button: Parameter selection and numerical modification;
Valve model rotary dial switch;
Measurement socket: v (internal given) Ia、Ib、 Reference location ⊥.
Technical parameters
General environmental parameters
Project specifications
Working temperature: 0…+60 ℃
Storage temperature -40…+70 ℃; Storage, light avoidance, UV resistance
Relative humidity 10-95% RH, condensation is prohibited
Install vertical DIN rail TH35-7.5/15; Gap between upper and lower ventilation ≥ 2 cm; Gap between adjacent components ≥ 1 cm in environments above 50 ℃
Maximum altitude of 2000 meters
Anti vibration impact meets EN60068 series vibration and impact testing requirements
EMC complies with EN 61000-6-2/61000-6-3, CE, RoHS
Electrical parameters
Project values
Power supply UB DC24 V; operating range 18-36 V; maximum ripple 2.5 Vpp
Power consumption<48 W; maximum current<2 A; startup surge current<4 A
External fuse 3.15 A delay type
The maximum output current of the electromagnet is 2.7 A, with PWM short-circuit protection
Valve cable (1.5 mm ²) with a maximum length of 50 mm
Simulate voltage input impedance of 200 k Ω; current input load resistance of 100 Ω
Simulated actual value output: 0~± 2.5 V, minimum load impedance 1 k Ω
Digital input DI activation level 11-36 V; shutdown -3-5 V
Slope time 0.01… 30 seconds
Zero point adjustment ± 10%
Step level S 0-50%
Instruction attenuation G 70-110%

Analog input:
A5 voltage type: single electromagnet 0…+10 V; double electromagnet 0… ± 10 V
F5 current type: 4-20 mA.
Valve dial code selection table
VT-MSPA1 (single electromagnet)
Dial gear corresponds to valve/pump:
4-0: DBE10Z overflow valve; 4-1: DRE10Z pressure reducing valve
4-2/4-3: (Z) 3DRE6 pressure reducing valve
4-4: Pump Control 4 (1.9A, A10VSO EC4/A15VSO U7)
4-5: Pump Control 5 (2.7A, A10VSO EB4/A15VSO U8)
9-6: Universal 0.8 A; 9-7: Universal 1.6 A; 9-8: Universal 2.5 A
VT-MPCA2 (Dual Electromagnetic)
0‑1:4WRA6; 0‑2:4WRA10; 0‑3:4WRZ; 0‑4 /0‑5:3DREP6; 0‑6:DBEP6;
3-7: Pump Control 1 (0.74 A, A4CSG EP)
9-6: Universal 0.8 A; 9-7: Universal 1.6 A; 9-8: Universal 2.5 A.
The universal gear can drive other third-party proportional electromagnets without position feedback and set the maximum output current.
LED indicator status description
DI (yellow): constantly on/off displays the digital input level; Flashing=Standard Setting Mode.
Ready (red green dual color)
Green constantly on: module ready;
Red constantly on: malfunction;
Red and green flashing alternately: valve parameters have been modified;
Red flashing: invalid dial valve number;
Green flashing: Expert parameter setting mode.
Other LEDs indicate: slope, zero/pilot current, gain G, step S, and four quadrant status.
Key points of project planning
EMC cabling
Separate the space between signal lines and power cables, and prohibit parallel wiring;
The maximum length of unshielded cables is 30 meters; shielded cables must be used for cables larger than 30 meters;
The shielding layer should be grounded according to the manual; Stay away from wireless devices (distance>1m).
When there is a large fluctuation in the power supply voltage, an external filtering capacitor of ≥ 2200 μ F should be connected; Multiple modules can be equipped with VT11110 capacitor modules, with a maximum of 3 amplifiers.
Keep the ventilation ducts above and below the module unobstructed and not obstructed by surrounding devices.
Default parameters are already available at the factory; After replacing the valve, it is necessary to reset the dial and set parameters such as zero point and slope.