Uncategorized

Bosch Rexroth VT-MSPA Proportional Valve Amplifier

Product model and material

Order code format: VT-MSPA – {1/2} -2X/{A5/F5}/000/000

MSPA1: Single electromagnetic drive (pressure valve, variable pump)

MSPA2: Dual electromagnetic drive (4WRA and other bidirectional proportional directional valves)

A5: Voltage command input (single electromagnet 0…+10   V; double electromagnet 0… ± 10   V)

F5: Current command input 4-20 mA

Model Material Number

VT‑MSPA1‑2X/A5/000/000 R901439034

VT‑MSPA1‑2X/F5/000/000 R901439036

VT‑MSPA2‑2X/A5/000/000 R901439037

VT‑MSPA2‑2X/F5/000/000 R901439038

Main functional features

Command input: differential voltage 0… ± 10   V or 4-20   mA current; Has reverse polarity protection.

Slope generator: supports single slope mode (shared by all quadrants) or 4-quadrant independent slopes (positive and negative rise, positive and negative fall are set separately); The slope time range is 0.01-30 seconds. The slope does not change the characteristic curve of the valve.

Zero offset Z/B: Zero/pilot current adjustment, with an adjustment range of ± 10%.

Instruction decay G: Scale the external given instruction by 70-110%.

Step level S: Set the output step current to 0-50% to overcome the valve dead zone.

Built in valve characteristic curve generator: rotate dial to select valve model, call pre stored valve characteristics; Expert mode can also fine tune the pilot current, step level, and maximum electromagnetic current; The A/B electromagnets of VT-MPCA2 can independently set the maximum current.

Current closed-loop controller: Real time collection of the actual current of the electromagnet, and closed-loop adjustment with instructions.

PWM clock output stage: clock frequency 95-505 Hz (automatically adapted with valve model/supply voltage); Output short circuit protection; Cable breakage detection.

The digital input DI can be configured with four functions: enable/reverse command/ramp switch/single/four quadrant ramp switching.

Digital output ready: Output a ready signal when there are no internal faults, the cable is intact, and the power supply is normal.

Panel human-machine interface: LED status indicator light, SET confirmation button,+/- parameter increase/decrease button, valve type rotary dial; The measuring socket can measure: the actual current Ia of the internal given v and A electromagnet, and the actual current Ib of the B electromagnet.

Hardware structure and terminals

Appearance: DIN TH35 rail module, glass fiber reinforced nylon shell, weight 0.14 kg; protection IP20.

Connectors: 3 sets of spring plug terminals XH1 (power supply+electromagnet), XH2 (DI/DO), X2A (analog given, actual value output).

Terminal allocation:

XH1: Power supply 24VDC, electromagnetic coil B ±

XH2: Digital input DI, Ready output, Electromagnetic coil A ± (MSPA2 only)

X2A: ± instruction given input; ± Actual value analog output (0~± 2.5   V, representing electromagnetic current)

Front panel components:

LED status indicator array;

SET button: Confirm parameters and enter expert mode;

+/-Button: Parameter selection and numerical modification;

Valve model rotary dial switch;

Measurement socket: v (internal given) Ia、Ib、 Reference location ⊥.

Technical parameters

General environmental parameters

Project specifications

Working temperature: 0…+60 ℃

Storage temperature -40…+70 ℃; Storage, light avoidance, UV resistance

Relative humidity 10-95% RH, condensation is prohibited

Install vertical DIN rail TH35-7.5/15; Gap between upper and lower ventilation ≥ 2   cm; Gap between adjacent components ≥ 1   cm in environments above 50 ℃

Maximum altitude of 2000 meters

Anti vibration impact meets EN60068 series vibration and impact testing requirements

EMC complies with EN 61000-6-2/61000-6-3, CE, RoHS

Electrical parameters

Project values

Power supply UB DC24   V; operating range 18-36   V; maximum ripple 2.5   Vpp

Power consumption<48   W; maximum current<2   A; startup surge current<4   A

External fuse 3.15   A delay type

The maximum output current of the electromagnet is 2.7 A, with PWM short-circuit protection

Valve cable (1.5 mm ²) with a maximum length of 50 mm

Simulate voltage input impedance of 200   k Ω; current input load resistance of 100   Ω

Simulated actual value output: 0~± 2.5   V, minimum load impedance 1   k Ω

Digital input DI activation level 11-36   V; shutdown -3-5   V

Slope time 0.01… 30 seconds

Zero point adjustment ± 10%

Step level S 0-50%

Instruction attenuation G 70-110%

Analog input:

A5 voltage type: single electromagnet 0…+10   V; double electromagnet 0… ± 10   V

F5 current type: 4-20 mA.

Valve dial code selection table

VT-MSPA1 (single electromagnet)

Dial gear corresponds to valve/pump:

4-0: DBE10Z overflow valve; 4-1: DRE10Z pressure reducing valve

4-2/4-3: (Z) 3DRE6 pressure reducing valve

4-4: Pump Control 4 (1.9A, A10VSO EC4/A15VSO U7)

4-5: Pump Control 5 (2.7A, A10VSO EB4/A15VSO U8)

9-6: Universal 0.8 A; 9-7: Universal 1.6 A; 9-8: Universal 2.5 A

VT-MPCA2 (Dual Electromagnetic)

0‑1:4WRA6; 0‑2:4WRA10; 0‑3:4WRZ; 0‑4 /0‑5:3DREP6; 0‑6:DBEP6;

3-7: Pump Control 1 (0.74   A, A4CSG EP)

9-6: Universal 0.8 A; 9-7: Universal 1.6 A; 9-8: Universal 2.5 A.

The universal gear can drive other third-party proportional electromagnets without position feedback and set the maximum output current.

LED indicator status description

DI (yellow): constantly on/off displays the digital input level; Flashing=Standard Setting Mode.

Ready (red green dual color)

Green constantly on: module ready;

Red constantly on: malfunction;

Red and green flashing alternately: valve parameters have been modified;

Red flashing: invalid dial valve number;

Green flashing: Expert parameter setting mode.

Other LEDs indicate: slope, zero/pilot current, gain G, step S, and four quadrant status.

Key points of project planning

EMC cabling

Separate the space between signal lines and power cables, and prohibit parallel wiring;

The maximum length of unshielded cables is 30 meters; shielded cables must be used for cables larger than 30 meters;

The shielding layer should be grounded according to the manual; Stay away from wireless devices (distance>1m).

When there is a large fluctuation in the power supply voltage, an external filtering capacitor of ≥ 2200 μ F should be connected; Multiple modules can be equipped with VT11110 capacitor modules, with a maximum of 3 amplifiers.

Keep the ventilation ducts above and below the module unobstructed and not obstructed by surrounding devices.

Default parameters are already available at the factory; After replacing the valve, it is necessary to reset the dial and set parameters such as zero point and slope.

Leave a Reply