Uncategorized

Rexroth Indramat System200 series BTV20.3 PC based industrial control panel

Product Overview

Product positioning: PC based industrial operation panel, with up to 8 slots inside the chassis, capable of inserting NC controllers, independent PLCs, and fieldbus boards; It is both a human-machine operation display terminal and can integrate a complete set of control hardware.

Hardware basic configuration

Slot‑CPU:Pentium‑SLOT‑CPU, Minimum 300MHz, integrated graphics card, 4MB video memory; Standard memory 64MB (optional 128MB); Minimum 3GB hard drive;

Screen: 10.4-inch TFT color display screen;

Storage: 3.5-inch floppy drive; Optional smart card reader Smart Card;

Power supply options: 115-230VAC wide AC or 24VDC DC power supply.

Front panel features

4mm thick aluminum panel, chemically corrosion-resistant raised polyester key film; When closing the floppy drive flip cover, the front panel protection level is IP65, and the back of the chassis is IP20;

Built in machine function buttons and PLC function buttons with replaceable insert labels; Equipped with a key switch for safety function locking.

Optional extension module

Independent PLC module (INTERBUS-S/PROFIBUS-DP);

CNC module with SERCOS fiber servo interface;

PCM-E02.1 Ethernet network card (10/100Mbit).

Software firmware: pre installed with Windows NT4.0 operating system, compatible with MTC200 CNC human-machine interface and ISP200-PLC software; Distinguish between German/English versions, firmware FWA needs to be ordered separately from software package SWA and authorized SWL.

​Usage standards

Compliance purpose

As a standalone device integrated operation/visualization/programming terminal; Also serves as the operation panel for external RECOM series controllers; Applied to multi axis machine tools such as lathes, milling machines, and machining centers.

The cable accessories must be specified in the manual to meet the temperature, humidity, and EMC environmental conditions.

Prohibited use scenarios

Underwater work, exceeding environmental conditions; Fields that have not been officially released by Rexroth (such as manned elevators, healthcare, nuclear power, mining, etc.). Unauthorized use will result in loss of warranty, and all risks will be borne by the equipment manufacturer.

General Electrical Safety Instructions

Following ANSI Z535 hazard classification DANGER/Warning/CAUTION, for the general safety chapter of Rexroth drive products:

Only certified personnel are allowed to operate high-voltage components with a voltage greater than 50V; Wait for 5 minutes for the capacitor to discharge after power failure; Protect the ground wire with a copper conductor of ≥ 10mm ²; The device cannot use RCD leakage protector; The low-voltage port can only be connected to PELV isolated ultra-low voltage equipment.

Wiring errors and hardware/software failures can cause unexpected device movement; Emergency stop, safety fence, and grating must be configured; The vertical axis requires external mechanical locking, and the built-in brake of the driver is not sufficient to ensure personal safety; Power off and lock during maintenance.

Personnel wearing pacemakers and metal implants are prohibited from approaching the equipment operation/assembly area.

Shutdown the shell at high temperature, wait for 10 minutes for it to cool down before touching it again; Batteries cannot be disassembled or incinerated and are treated as hazardous waste.

The manufacturer of the entire machine is responsible for ensuring that it complies with local machine directives and EMC regulations before it can be powered on for operation.

Front panel and keyboard

Soft drive flip area: built-in reset button (pen tip press, direct restart loses unsaved data), PS/2 external keyboard and mouse interface; Three status LEDs: POWER power supply, HDD hard disk access, and TEMP over temperature alarm.

Button grouping

Machine function keys: left L1-L8, right R1-R8, a total of 16, hardware directly connected to PLC, PLC program can directly read Boolean input signals;

OP operation key, F1-F9 function key;

General editing navigation buttons such as ESC, OK, SHIFT, PROG, DEL, CTRL, ALT, etc;

There are 14 PLC function buttons with LED indicator lights in S1-S14, which support customizable text for pull-out label strips;

Two levels of key switch: Operator/Prog programming mode, mapped to PLC input points, and can also control button LED output.

PLC addressing method: Machine keys, PLC keys, and key switches all have fixed% I input and% Q output LED addresses, and the manual provides complete address constants.

Keyboard language settings

External keyboard: Windows NT Control Panel “Keyboard Input Area” adds language layout;

The device has a built-in membrane keyboard: Install the BTV20 control panel mini program using the matching tool tray and select the layout of English/German/Italian/Spanish.

PC external keyboard key combination can simulate BTV local panel key operation.

Technical data

Project parameters

Processor Pentium SLOT CPU ≥ 300MHz

Memory standard 64MB, maximum expandable

Hard drive ≥ 3GB

Display 10.4 “TFT color

Slot 3 x PCI, 1 x PCI/ISA, 4 x ISA

Protection front panel IP65, chassis IP20

Overall dimensions (including front panel) 407 x 370 x 220 mm (width x height x depth)

Weight approximately 10.5 kg

Power supply AC 90-132/180-264V automatic range, maximum power consumption 250VA, heat dissipation 100-200W

Working temperature: 5-45 ℃; Storage and transportation -20~+60 ℃

Vibration and impact comply with EN60068-2-6/27 standards

Consumable components (not covered by warranty) such as fans, backlight tubes, floppy drives, hard drives, and motherboard backup batteries; Expected lifespan of approximately 5 years/20000 operating hours

Appearance and installation dimensions

Provide layout drawings for the front panel, rear view, side view, and bottom slot;

Panel opening size, M5 screw fixing installation plan; After installation, a ventilation gap of ≥ 20mm should be reserved around the back of the chassis.

Interfaces, Wiring, and Application Cases

SLOT-CPU onboard interface

COM1:RS232; SVGA video; 10Base-T Ethernet;

LPT1 parallel port printer; SIS (COM2) supports RS232/RS422/RS485 and can be configured through BIOS GPIO mode;

PS/2 external keyboard and mouse.

BIB05 plug-in board (PC variant model): Map the local panel buttons to ISA bus and INTERBUS bus; The dip switch sets the ISA base address, and the jumper selection is controlled by the ISA or INTERBUS button LED.

Multiple sets of practical wiring application example drawings

BTV20+INTERBUS connection BTA20/BTA10 handheld unit RECO12 I/O;

Connect BTC06 handheld operating unit;

SERCOS fiber optic interface connects to DIAX04 driver amplifier (up to 8-axis driver module).

Provide the configuration of pins and terminal resistors for the dedicated bus connectors INS0619/K01 and INS0645/K01.

SLOT-CPU motherboard hardware and AMIBIOS BIOS

SLOT-CPU (686LCD/MG) hardware specifications: AMD K6-III ≥ 300MHz; Onboard 64 bit SVGA graphics card, 4MB video memory; Supports TFT LCD screens and CRT monitors; Support EIDE hard drives and floppy drives; Equipped with a watchdog and RTC real-time clock (CR2032 lithium battery backup); Supports SIMM memory modules.

AMIBIOS setup program: Press Del to enter BIOS when booting up; Divided into six major settings pages: Standard, Advanced, Chipset, Power Management, PCI/PnP, and INSIDE tools;

Provide password management (administrator/user two-level passwords) and virus protection;

Support Optimal configuration and Fail Safe default configuration;

Power on self-test beep error code;

The INSIDE tool page can set industrial specific parameters such as serial port mode, temperature alarm, fan overload, watchdog timeout, etc.

Steps for disassembling and assembling SIMM memory modules.

PCM-E02.1 Ethernet board

PCI bus network card, supporting 10/100M adaptive; Simultaneously equipped with RJ45, AUI, and BNC coaxial media interfaces;

LED status lights: 10M link, 100M link, ACT data activity;

Electrical and environmental parameters.

Optional smart card reader

Installed in the flip cover position of the floppy drive, supporting ISO7810 ID-1 standard IC card, chip centered type;

Mechanical bullet insertion structure; Internal flat cable X101 connects to the motherboard; Also supports external service floppy drive units;

Complete mechanical, electrical, vibration and impact technical indicators.

Ordering Information

BTV20.3 model coding rules, with fields including product series, version, function type (A=MTA, C=MTC, P=PC, S=ISP), keyboard type, memory, machine keys, system configuration, power supply, driver (floppy drive/smart card), firmware tag FW.

Three types of configuration codes: BTV20.3C(MTC‑C CNC)、BTV20.3S(ISP‑S PLC)、BTV20.3A(MTA‑A), Define PCI/ISA/PC104 slots to allow installation of boards such as MTS-P, PROFIBUS master-slave, INTERBUS master, SERCOS axis card, Ethernet card, etc.

Accessories list: complete set of cables IKB0015, IKS0056, D-Sub connector, lockable soft drive flip SUP-M01-BTV20.

Leave a Reply

Your email address will not be published. Required fields are marked *