Banner XS/SC26&SC10-2 Safety Controller
Core positioning and applicable products
1. Attributes
Applicable: XS/SC26 series+SC10-2 series safety controllers
Safety level: Cat.4/PL e/SIL CL3 (highest industrial safety level)
Compliant with standards: ISO 13849-1, IEC 61508, IEC 62061, EN ISO 12100
2. Two major product series
(1) XS/SC26 Scalable Security Controller
Model: XS26-2, SC26-2, XS26-ISD (with ISD diagnosis)
Features: Expandable up to 8 I/O modules, supports secure input/output expansion, EtherCAT gateway
Interfaces: Micro USB, Ethernet (some models), LED display screen (some models)
Application: Large scale equipment, robot workstations, multi area security protection, stamping equipment
(2) SC10-2 Compact Safety Controller
Model: SC10-2roe
Features: Fixed I/O, 2 sets of 6A safety relay outputs, 10 inputs (4 convertible)
Advantages: Replace 2 independent safety relays, high cost-effectiveness, simple wiring
Application: Small devices, single machines, simple safety circuits
Overview of Core Functions
All types of secure input support
Emergency stop, rope switch, safety door switch, safety light curtain, manual operation, safety carpet, activation device, protective stop, ISD series diagnostic equipment.
Advanced security logic function
Bypass, Muting, Delay, Latch Reset, Press Control, Valve Monitoring (AVM), External Device Monitoring (EDM).
Intelligent Diagnosis
ISD series diagnosis: Real time acquisition of sensor status, voltage, temperature, distance, and error codes.
network communication
Ethernet EtherNet/IP、Modbus TCP、PROFINET、EtherCAT。
Automatic Terminal Optimization (ATO)
Automatically share test pulse terminals, reduce wiring, and maximize I/O utilization.
Configuration and simulation
PC software graphical configuration, simulation mode, online monitoring, fault logs, configuration backup (SC-XM2/3 storage disk).
Hardware specifications
1. Electrical parameters
Power supply: 24V DC ± 20% (SELV/PELV)
Safe output:
XS/SC26: Solid state output (0.5A/channel), relay output (6A/contact)
SC10-2:2: 2 sets x 3 NO 6A safety relays
Input: PNP/universal contact, dual/single channel, supports Category 2/3/4
Insulation/protection: IP20, built-in EMC anti-interference
2. Machinery and Environment
Installation: 35mm DIN rail
Working temperature: 0~+55 ° C
Shock/Vibration: Complies with IEC 61131-2
Certification: CE, UKCA, UL, cUL
3. Expansion module (XS/SC26 only)
XS8si/XS16si: Secure Input Extension
XS2so/XS4so: Solid state secure output
XS1ro/XS2ro: safety relay output
XSeCAT: EtherCAT Communication Gateway
Installation and Wiring (Core Specification)
safety principle
The safety output must directly control the MPCE (Main Hazardous Moving Element) and must not pass through a regular PLC.
EDM/AVM mandatory recommendation
External Device Monitoring (EDM): Monitor whether the contactor/relay is stuck
Valve monitoring (AVM): monitoring clutch/valve group actions
Wiring taboos
Inductive loads must be equipped with surge absorbers (load side)
Do not cross connect the absorber on the safety output contact
Public 0V line resistance ≤ 10 Ω to prevent accidental locking of the machine
ISD chain connection
Up to 30 meters per chain, supports cascading, automatically identifies the number and sequence of devices.

The entire process of software configuration
1. Configuration steps
New Project → Select Controller Model
Add secure/non secure inputs and status outputs
Drag and drop logic/function blocks to build security logic
Set delay, reset EDM/AVM、 interlocking
Simulation testing → Writing to controller → Confirming configuration
Network settings (IP, protocol, virtual I/O)
2. Core functional blocks
Bypass: Manual bypass (key switch)
Muting: Automatic blocking (material passage)
Two Hand Control: Two Hand Control (compliant with ISO 13851)
Press Control: Press Control (Top Dead Center, Bottom Dead Center, Sequential Stop SQS)
Delay/Latch Reset: Delay, latch reset
EDM/AVM: External Monitoring
3. Virtual I/O
Virtual input: reset, start/stop, disable enable
Virtual Output: Fault, Running, Bypass, Shielding, Waiting for Reset
Supports 256 channels of virtual state output (network transmission to PLC/HMI)
Network Communication (Industrial Ethernet)
Support agreement:
EtherNet/IP
Modbus TCP
PROFINET
EtherCAT (requires XSeCAT module)
Function: Remote configuration, online monitoring, fault upload, virtual I/O interaction
Security: Password protection, default password must be changed to enable Ethernet configuration
Examples of Safe Applications and Wiring
Emergency stop circuit: dual circuit Cat.4、 Manual reset
Safety door interlock: with lock switch, EDM monitoring
Safety light curtain+Muting: automatic release of materials
Two handed operation: anti one handed, anti binding
Full functional safety of the press: both hands+light curtain+SQS+foot pedal
ISD Chain Safety Gate: Diagnoses every sensor
Fault diagnosis and troubleshooting
1. Fault type
Input faults: short circuit, disconnection, asynchronous
Output faults: overload, short circuit, sticking
EDM/AVM malfunction: External components not responding
ISD malfunction: equipment loss, sequence error, unpaired
Network failure: IP conflict, connection interruption
2. Troubleshooting tools
LED status light
Software real-time monitoring (Live Mode)
Fault Log
Configure logs and module information queries
3. Recovery method
Manual reset
System Reset
power on again
Rewrite configuration