Rexroth IndraDyn H frameless synchronous spindle motor

Product Introduction

Product positioning: High speed frameless permanent magnet synchronous kit motor, built-in three-phase winding stator+permanent magnet rotor, with integrated water cooling structure; Featuring a wide constant power range, short start-up time, and low rotor temperature rise, it is specifically designed for direct drive of machine tool spindles. The motor is installed between the spindle bearings to achieve high rigidity, and one drive can complete the functions of the lathe main spindle and C-axis.

Typical applications: Turning, milling, and grinding equipment for machine tools; Machining centers, specialized machines, and automated production lines.

Document description: The manual includes safety instructions, technical parameters, and operation guidance; Simultaneously provide a list of supporting reference documents; Reminder: Compliance with German/European/international standards is required.

Performance range: Covering a total of 8 machine base specifications from Size102 to Size382, with a large torque span, covering from small torque to large torque.

General safety regulations for electrical drives

According to ANSI Z535 hazard level classification: DANGER (fatal injury), Warning (potentially fatal injury), CAUTION (personal injury/property damage). Main risk points and protection requirements:

High voltage electric shock risk: For components with a voltage greater than 50V, power must be cut off during maintenance; After power failure, wait for the capacitor to discharge for 30 minutes; The protection ground wire requires a copper conductor cross-sectional area of ≥ 10mm ²; This drive system cannot use residual current device (RCD). Distinguish between the high voltage of the main circuit and the PELV protection ultra-low voltage (0-50V), and only isolate PELV equipment can be connected to the low voltage port.

Unexpected dangerous movements: wiring errors, parameter errors, encoder failures, firmware bugs can all cause misoperations. Require the installation of safety fences, safety barriers, and emergency stops; The vertical axis requires additional mechanical locking/external brake, and the motor’s built-in brake is not sufficient to ensure personal safety; Disconnect the main power supply and lock it during maintenance.

Magnetic field hazards: Personnel wearing pacemakers, metal implants, and hearing aids are prohibited from entering the motor assembly, operation, and storage areas. If they need to enter, they must first consult a doctor.

High temperature burns: After shutting down, cool down for at least 10 minutes before touching the casing.

Risk of handling and assembly: Suitable lifting equipment must be used, protective gear must be worn, and standing under heavy lifting objects is prohibited.

Battery and pressure system safety: Do not disassemble/heat rechargeable batteries; Water cooling belongs to a pressurized system and must be depressurized and drained before disassembly.

Important statement: Failure to comply with the safety instructions in the manual will result in the manufacturer not being held responsible for any damages and the warranty being void.

Usage standards

Compliant use: limited to machine tool spindle direct drive only; Accessories and cables must be specified in the user manual; Must meet environmental conditions; The entire equipment must comply with local regulations before it can be powered on for operation; EMC electromagnetic compatibility must meet national standards.

Prohibited (improper) use: working underwater, exceeding temperature and humidity/vibration impact conditions; Other special scenarios without permission from Rexroth (lifting, elevators, medical, nuclear power, mining, etc. cannot be used directly). The manufacturer of the complete machine is responsible for verifying that the motor is compatible with their own equipment.

Technical data

Standard basis: Following EN   60034-1, the data benchmark is water-cooled and the medium is water; Define the S1 continuous operation and S6 intermittent cycle working system, and provide the formula for calculating the load duration rate ED.

Parameter definitions: rated torque, rated speed, rated power, rated current, maximum torque, maximum current, rotor moment of inertia, torque constant, voltage constant, winding resistance/inductance, thermal time constant, maximum speed, pole pairs, etc.

Torque speed characteristics: affected by DC bus voltage; Provide a conversion formula to 750VDC based on the reference DC bus 540V; The maximum torque that can be output is strongly correlated with the ability of the supporting drive. The Rexroth IndraDrive drive can fully utilize its performance, while third-party drives will lose 10-15% of the rated torque.

Machine Base Specification Data Sheet (Size102 and 142 are preliminary data, 162-382 is the official data sheet)

Main common conditions:

Environmental temperature: 0~+40 ℃; Storage and transportation temperature -20~+80 ℃; Insulation level F; Protection level IP00;

The water inlet temperature for water cooling is 10-40 ℃, and the maximum inlet pressure is 5bar;

Each specification is divided into different iron core lengths such as A/B/D/F, and the longer the iron core, the greater the output torque.

Dimensional drawings

Covering the complete set of engineering drawings for Size162-382, each machine base includes:

Whole machine: Axial cooling interface rotor 1N; Axial cooling interface rotor 2N; Partial specifications (182, 312) provide radial cooling interface versions;

Individual drawing of stator (MSS);

Two types of rotor structures:

1N: Smooth inner hole (optical hole);

2N: Step interference fit hole; The drawing tolerances follow the geometric tolerance standards of DIN ISO2768-1, DIN7168, and DIN ISO1101.

Model coding rules

The motor is a kit, and the stator MSS and rotor MRS have independent model codes. The sixth digit of the IndraDyn H version model is the number “2”.

Rotor MRS encoding field: Product code MRS → Machine base size → Iron core length letter → Rotor hole structure (1N optical hole/2N stepped interference fit) → Rotor inner diameter → Other options.

Stator MSS encoding field: Product code MSS → Machine base size → Iron core length letter → Winding code (determining rated speed) → Cooling method F Water cooling → Cooling joint A axial/R radial → Encoder configuration (motor body without encoder N0) → Electrical connection CN cable lead out → Other options.

Important: The motor body does not integrate an encoder, which is an external accessory. The manual provides complete coding examples for each specification of Size102-382.

Connection technology

Power connector and grounding: specify the minimum cross-sectional area of the cable and the requirements for the grounding conductor; Supports two wiring methods: junction box and coupling.

Temperature sensor: The stator is equipped with a built-in temperature monitoring sensor for overheat protection.

Water cooling pipeline: working pressure, interface definition, distinguishing axial/radial cooling joints.

Encoder: The encoder is an external supporting component and is not included in the motor body.

Application Design Considerations

Environmental conditions: altitude, ambient temperature, allowable humidity; Vibration impact limit; The protection level is IP00, and the entire machine tool needs to provide protection.

Water cooling system design: coolant medium, inlet water temperature, temperature rise limit, thermal behavior, cooling circuit selection calculation; Key points of water cooling system structure.

Temperature monitoring and motor rotation definition.

Principle of rotor and spindle assembly

1N: Smooth inner hole rotor;

2N: stepped interference fit hot sleeve rotor; Provide detailed specifications for the spindle diameter tolerance and fit requirements.

The installation principle of stator inside the spindle box housing.

Regenerative energy processing: Requirements for the driver in the feedback condition of motor power generation.

External supporting components: key points for selecting encoders; Key points for selecting spindle bearings.

Handling, transportation, and storage

Factory inspection and customer side inspection upon arrival; Delivery scope description.

Identification method for component identification.

Transportation protection requirements and storage environmental conditions; The rotor is equipped with strong permanent magnets, and there are special precautions for storage.

Assembly instructions

The assembly of this motor is based on the core process of hot sleeve (interference heating assembly).

General principles for assembly safety, requirements for tooling tools; Specification for the use of Loctite thread locking adhesive.

Hot fitting of rotor onto main shaft: For 1N optical hole rotor and 2N stepped interference fit rotor, check and heat the complete steps of hot fitting before assembly.

Measures for handling assembly errors; Requirements for rotor dynamic balance.

Rotor disassembly: Emphasize the disassembly process of 2N stepped interference fit rotors.

Assembly of stator into spindle housing: preparation before assembly, installation steps, wiring; Dismantling of stator.

The complete installation and disassembly process of the spindle assembly.

Power on start-up, operation, and maintenance

Before starting, check the mechanical and electrical components to ensure that all materials are complete.

Complete startup process:

Parameter settings: motor body parameters; External encoder parameters; Driver restriction parameters;

Encoder polarity confirmation; Motor commutation tuning; Control loop debugging and optimization.

Operation, shutdown, and disassembly.

Maintenance inspection items: Regular inspection of the motor body, water cooling circuit, and electrical circuit.

Troubleshooting checklist:

Overheating of the casing; The temperature inside the motor is high, but the temperature inside the casing is normal;

The whole machine vibrates greatly; Unable to reach the set position.