Rexroth IndraControl VCP 08 Industrial Small Operator Panel
Product Overview
Product Introduction: Compact panel type operator terminal, with a full circle rubber sealing ring on the back cover, supporting any installation posture; There are two major variants of hardware: ① Standard serial port version; ② Fieldbus versions (DeviceNet/INTERBUS/PROFIBUS-DP). The front panel is a 3mm aluminum panel covered with chemical resistant polyester key film.
Operating system: The device is equipped with dedicated firmware, which can be downloaded and updated using the accompanying software VI Composer.
Debugging and startup process: Complete the panel opening installation, connect 24V power supply, and connect the controller or fieldbus.
Usage Standards
Compliance Applicable Scenarios: Used for human-machine interaction of single/multi axis devices, achieving device operation and status visualization; Typical equipment: handling and assembly equipment, packaging machinery, printing and papermaking equipment, machine tools. Only accessory cables specified in the manual are allowed to be used, and must meet the environmental conditions specified in the document.
Prohibited use (improper use): working underwater, exceeding temperature and humidity conditions; Not allowed for use in scenarios such as lifting, manned elevators, medical, nuclear power, mining, etc. where Rexroth has not officially issued a license. The manufacturer of the complete machine needs to confirm the compatibility of the equipment and comply with local regulations. Misuse may result in loss of warranty, and the risk is borne by the user.
General Electric Drive Safety Instructions
Adhere to ANSI Z535 hazard classification (DANGER/Warning/CAUTION), consistent with the general safety chapter content of the Rexroth driver series.
High voltage electric shock protection: Only certified personnel are allowed to work on components with a voltage greater than 50V. After the power is cut off, wait for the capacitor to discharge, and protect the ground wire with a copper conductor of ≥ 10mm ²; This device cannot use residual current device RCD; Distinguish between high voltage and PELV protection ultra-low voltage.
Unexpected equipment movement risk: Wiring, parameter, and encoder failures can all cause misoperation; Need to configure safety fences, light barriers, and emergency stops; The vertical axis must be equipped with external mechanical locking, and the equipment itself does not have personal safety protection capabilities.
The health risks of magnetic fields to pacemaker and metal implant personnel; High temperature burns; Handling and assembly protection; Battery safety; Pressure system protection.
Important statement: Failure to comply with safety instructions does not hold the manufacturer responsible for any damage.
Technical Data
mechanical structure
Front panel: 209mm × 159mm, 3mm painted aluminum plate; The total weight of the machine is about 800 grams;
Protection level: front panel IP54, back IP20;
Installation hole size: 199 mm × 139 mm; installation depth is about 58 mm (excluding connectors); Suitable for cabinet board thickness of 1-8mm.
keyboard
36 short stroke tactile feedback buttons in total; Travel of 0.5 mm, triggering force of 2-3 N, button lifespan of approximately 1 million times; Contains 12 custom function keys F1-F12, numeric editing keys, navigation direction keys, special keys such as Print, Help, Quit, etc; The function keys can be replaced and the identification strip can be pulled out.
Display unit
LCD with LED backlight, resolution of 120 × 32 pixels; Yellow green background with black characters; Normal font 4 lines x 20 characters; Supports both regular and enlarged fonts; Contrast software adjustable with temperature compensation; The lifespan of LCD and backlight is 100000 hours each.
Electrical parameters
Power supply: 24 VDC (SELV safe ultra-low voltage); Allow 19.2~30.2 VDC with a maximum ripple of 10%; Power consumption is about 10 W, peak current<0.5 A; built-in self recovering semiconductor fuse with reverse protection.
Hardware core: Z84 CPU 10 MHz; 256 KB Flash program storage; 128KB battery backup CMOS RAM; Equipped with a watchdog and real-time clock RTC.
Interface Classification
Standard serial port (SER1, electrically isolated): TTY/20mA current loop, RS485, RS232c (choose one of three, cannot be used simultaneously);
SER2 RS232c (non isolated): specifically designed for downloading and uploading programs, connecting printers, and scanners;
Choose one of the three variants of fieldbus: DeviceNet, INTERBUS, PROFIBUS-DP, all of which are electrically isolated;
The model code determines the hardware interface type, and a terminal can only select one type of bus.
environmental conditions
Working temperature: 0~+50 ℃; Storage and transportation -20~+70 ℃;
Relative humidity of 10-95%, no condensation; Pollution level 1, overvoltage category II;
Meet the full set of EMC anti-interference and emission standards EN61000 series, and equipment standards EN61131.
Dimensions and Installation
Installation method: Insert the cabinet panel from the front and tighten the M4 nut on the back; The maximum tightening torque is 1.2 Nm; the sealing ring must be evenly compressed to ensure IP54.
Heat dissipation requirement: Reserve a ventilation gap of ≥ 30mm around the equipment; Horizontal installation should avoid the accumulation of heat sources below.
Provide complete drawings: front panel outline, cabinet opening drawing, side view installation depth drawing.
Display and Operation Components
LCD contrast setting: set through the system variable LcdFntrast (-25~+70, default+25) software; If the screen is completely blurry, you can use the backplane user mode switch to restore the factory contrast without clearing the engineering program. LCD screen rupture may contain corrosive liquid, contact is prohibited.

Keyboard partitioning
Edit buttons: Enter numbers and symbols, and use Shift to input letters;
Navigation keys: cursor up, down, left, right Home;
Special buttons: Help online help, Print, Quit exit, Enter confirm, Data Release editing mode switch, Delete delete;
F1-F12 has a total of 12 function keys: functions can be freely assigned in VI Composer software; The backboard can be inserted with replacement function label strips without damaging the seal.
Backplane user mode switches S1-S4: used for special modes such as firmware download and contrast restoration.
Detailed Definition of Interface
The X3 composite connector (25 pin D-Sub) includes SER1 (Multiprotocol Multiplexing) and SER2. SER1 can only enable one physical interface at a time.
TTY/20mA current loop: supports active/passive modes, provides pin definitions and terminal switch settings.
RS485: point-to-point or multi-point bus; The backplane hardware terminal is connected to a resistance switch, and the point-to-point must be turned on; Multipoint is only enabled at both ends of the bus, providing logic level definitions and resistance parameters.
SER1 RS232c: isolated point-to-point; The terminal switch is turned off.
SER2 RS232c: No electrical isolation, only for downloading, printing, and scanning.
Fieldbus interface (X2 connector)
DeviceNet: Dual 9-pin D-Sub (input/output loop), baud rate cable length comparison table, diagnostic LED status description; Both ends of the bus must have a terminal resistance of 120 Ω.
INTERBUS: IN/OUT loop interface, diagnostic LED status, cable requirements.
PROFIBUS-DP: 9-pin D-Sub, Class A standard cable, baud rate and maximum cable length, terminal resistance at both ends of the bus.
D-Sub connector shielding specification: The shielding layer is extensively pressed onto the connector housing to ensure grounding and stress relief.
X1 power interface: 3-pin Phoenix COMBICON terminal, 24VDC power supply pin definition, cable cross-sectional area 0.75-2.5 mm ².
Maintenance, Installation and Wiring
The device body is maintenance free, only the backlight and battery are consumables; Hardware maintenance must be operated by professionals; The user is responsible for backing up the engineering data themselves, and the manufacturer does not bear the loss of data.
Open the box and inspect for transportation damage; Equipment nameplate identification includes order number, material number, voltage, and serial number; The firmware version can be viewed on the brief boot initialization interface.
Power wiring steps, cable handling, wire nose, shielding treatment.
Front panel cleaning: Only wet cloth wiping is allowed.
Fuse: Semiconductor self recovery, recovers after overload and power-off cooling, cannot be replaced.
Backup battery (RTC+RAM power supply): with a nominal lifespan of 5 years, it is recommended to replace it regularly every 4 years; Can be charged to replace batteries and protect data in RAM; When the battery is depleted, a “Change battery” alarm will be reported, and time, formula, and parameters will be lost; Waste batteries should be isolated and recycled as hazardous waste.
Ordering Information
Model coding rule VCP08.1BTN-XX-NN-FW
Product series, version, panel type BT=36 key 120 × 32LCD; Interface options: RS (serial port)/DN (DeviceNet)/IB (INTERBUS)/PB (PROFIBUS-DP); FW stands for firmware.
Accessories list: Replace batteries, download cables, various bus cable material numbers.