Bonner Q45U series short range analog output ultrasonic sensor
Core model and output method
Model outgoing line/interface
Q45ULIU64ACR 2m cable
Q45ULIU64ACRQ 5-pin 7/8in-16UNF quick insertion
Q45ULIU64ACRQ6 5-pin M12 quick plug
Q45ULIU64ACR W/30 9m cable
Key electrical specifications
Supply voltage: 15~24VDC (ripple ≤ 10%), power consumption 100mA
Analog output (choose one)
Voltage: 0~10VDC, maximum 10mA
Current: 4~20mA, load 1~500 Ω
Output slope: can be set to positive/negative (as the distance increases, the output increases/decreases)
Response time: adjustable in 6 levels, 40ms~1.28s
Resolution: 0.25mm; Repetition accuracy: ± 0.1%
Testing and Performance Parameters
Detection distance: up to 100mm, up to 1400mm
Minimum window width: 10mm
Temperature compensation: 0~50 ℃ error ≤ 1%, full temperature range ≤ 2.5%
Environmental protection: IP67, NEMA 6P, resistant to 1200psi flushing
Working temperature: -25 ℃~+70 ℃
DIP switch configuration (4 bits)
Switch function setting instructions
Output slope ON=positive slope; OFF=Negative Slope (default)
Output mode ON=current; OFF=Voltage (default)
3 echo loss ON=Min Max; OFF=Hold (default)
4 default output ON=maximum value (default); OFF=minimum value
Indicator light function
Green: constantly on=power supply; Flashing=output fault
Red: Always on=Received echo; Scintillation intensity=echo intensity
Yellow: Always on=Target within window
5-segment LED: displays the relative position of the target, flashes beyond the limit prompt

Programming Settings
1. Local key programming
Press and hold the button for 2 seconds to enter programming
Place the target, short press to set the first limit value
Place the target, short press to set the second limit value
Automatically exit operation, timeout of 2 minutes
2. Remote programming
Signal line: yellow line, input * *+5~24VDC**
Logic: Consistent with local button timing, mutually exclusive use
Wiring Definition
Brown: Power Supply+
Blue: Power supply 0V
White: 4~20mA
Black: 0~10V
Yellow/Grey: Remote TEACH
Shielding: Grounding
Accessories and Machinery
Installation thread: M30 × 1.5
Bracket: SMB30s/SMB30C/SMB30MM
Cable: 2m standard, 9m optional, quick plug compatible with MBCC/MQDEC series
Key issues
Question 1: How to configure the output mode and slope of Q45U? How to deal with echo loss separately?
Answer: Use DIP switch 2 to switch between 0~10V voltage (default) or 4~20mA current; Switch 1 is set to positive/negative slope. Echo loss is controlled by switch 3: OFF is in hold mode (holding the value before loss); ON is Min Max mode (output to maximum/minimum, determined by switch 4).
Question 2: What is the temperature compensation effect of the sensor? What are the differences in accuracy between different temperature ranges?
Answer: Equipped with fully automatic temperature compensation; Within the range of 0~50 ℃, the window limit position error is ≤ 1%; Within the temperature range of * * -25~+70 ℃, the error is ≤ 2.5%; Every 20 ℃ temperature change will cause a limit deviation of about 3.5% * *.
Question 3: What are the two programming methods for Q45U? What is the minimum detection window? How to handle programming failures?
Answer: Supports local programming with the top button and remote programming with the yellow line, both of which are interlocked. The minimum window width is 10mm. In programming, long press the button * *>2 seconds * * to cancel and restore the original parameters; When the limit value is invalid, it will automatically return to the first step and reprogram.